\begin{document}$ ka\gg 1 $\end{document}), a Stochastic scattering limit is reached. Conversely, when \begin{document}$ ka\ll 1 $\end{document}, a Rayleigh scattering limit is observed. Furthermore, the backscattering coefficient is directly proportional to the grain size. As a general trend, larger grain sizes result in higher backscattering coefficient.Three sets of GH4742 specimens with different grain sizes are prepared for phased array ultrasound experiments. It can be observed that the experimental backscattering coefficients, root mean square (RMS) values, and the amplitude trend of time domain signal are consistent. To perform grain size inversion, the backscattering coefficients in the effective bandwidth range of the probe are selected. By utilizing the least-square method, the theoretical backscattering coefficient is employed to fit the curves of the experimental backscattering coefficients. The evaluation results are compared with those obtained by metallographic analysis. The results show that the grain sizes obtained by the proposed method have a maximum relative error of –22.7% and a minimum relative error of –3.7%."> - 必威体育下载

Search

Article

x

留言板

姓名
邮箱
手机号码
标题
留言内容
验证码

downloadPDF
Citation:

    Liu Yu, Tian Qiang, Wang Xin-Yan, Guan Xue-Fei
    PDF
    HTML
    Get Citation
    Metrics
    • Abstract views:1337
    • PDF Downloads:73
    • Cited By:0
    Publishing process
    • Received Date:12 December 2023
    • Accepted Date:07 January 2024
    • Available Online:18 January 2024
    • Published Online:05 April 2024