    • In order to improve the temporal resolution of photomultiplier tubes, our research group has conducted the in-depth research on photomultiplier tubes based on microchannel plates that are widely used at present. The time resolution of photomultiplier tube based on microchannel plate is limited by the transit time of photoelectric signal in each part, including the transit time of photoelectric signal in the transmission process of photocathode to microchannel plate, the transit time of photoelectric signal in microchannel plate time, the transit time of the photoelectric signal from the microchannel plate to the detector anode, and the transit time of the photoelectric signal on the anode to the electrode port. The transit time of the whole process has a certain degree of influence on the time information measurement of the optoelectronic signal. In this study, various parameters affecting the time resolution of the photomultiplier tube are analyzed, and it is found that the different positions of the photoelectron signal on the anode will bring errors to the measurement of the arrival time of the signal at the anode, and the photoelectric signal is transmitted to the electrode port at the affected point of the anode The spent time will cause the signal measurement time to lag behind the real time, which indirectly affects the time resolution of the system. Therefore, a specific study is carried out on the time measurement error of the signal on the anode, and it is determined that the difference of the photoelectron signal on the anode position is an important factor causing the signal time measurement error, and a simple and effective method of compensating for error is proposed. In the research process, the delay line anode is used, and the positional resolution principle of the photoelectric signal is used to obtain the position information of the photoelectron signal on the anode, and the position information is converted into the time information transmitted from the position to the electrode port. The theoretical value of the transit time on the anode is offset, eliminating unnecessary time in the time-of-arrival measurement of the photoelectron signal. The time measurement error of the optoelectronic signal is compensated for by this time information. The experimental results show that the error compensation method can effectively improve the time measurement accuracy of optoelectronic signals, and provide solutions and theoretical basis for improving the time resolution of photomultiplier tubes based on microchannel plates.
          Corresponding author:Dang Wen-Bin,Dang_wb@163.com
        • Funds:Project supported by the National Natural Science Foundation of China (Grant Nos. 61805199 ), and the Natural Science Foundation of Shaanxi Province (Grant No. 2020JM-578).
        [1]

        [2]

        [3]

        [4]

        [5]

        [6]

        [7]

        [8]

        [9]

        [10]

        [11]

        [12]

        [13]

        [14]

        [15]

        [16]

        [17]

        [18]

        [19]

        [20]

      • 端到端延迟/ns 平均幅值/mV 衰减/%
        X方向 4.75 286 42.8
        Y方向 6.15 336 32.8
        DownLoad: CSV

        随机位置点 到达时间测试值/ns 到达时间实际值/ns
        a 7.14 4.956
        b 6.78 5.019
        c 6.48 5.029
        d 5.925 4.747
        e 6.5 4.918
        f 5.381 4.351
        g 6.667 5.062
        h 6.358 4.932
        DownLoad: CSV
      • [1]

        [2]

        [3]

        [4]

        [5]

        [6]

        [7]

        [8]

        [9]

        [10]

        [11]

        [12]

        [13]

        [14]

        [15]

        [16]

        [17]

        [18]

        [19]

        [20]

      Metrics
      • Abstract views:3010
      • PDF Downloads:59
      • Cited By:0
      Publishing process
      • Received Date:17 June 2022
      • Accepted Date:28 July 2022
      • Available Online:09 November 2022
      • Published Online:20 November 2022

        返回文章
        返回
          Baidu
          map